본문 바로가기 주메뉴 바로가기

네트워크 분석기

HOME  >  제조사별  >  ROHDE & SCHWARZ  >   네트워크 분석기

ZVT (Multi-port Network Analyzer)

주요 스펙

Frequency Range
  • :300 kHz to 8 / 20 GHz
Port Number
  • :Up to 8 Port
Power Resolution
  • :0.01 dB
IF Bandwidth
  • :1 HZ to 1 MHz
Measurement time
  • :< 6 us
Key Facts

 - Multiport measurements, avoiding any time loss due to matrix control
 - Flexible configuration of test ports for balanced and single-ended measurements
 - True differential measurements and coherent signal generation
 - Enhanced performance by parallel measurements on several DUTs
 - Multichannel receiver with simultaneous sampling of channels, e.g. for phase measurements on antenna arrays
 - Automatic calibration units
 - Point-in-pulse and pulse profile measurements with up to 16 receivers
 - Up to 3 (ZVT20) or 4 (ZVT8) internal sources for flexible and efficient measurements on active devices, such as (double) converting transmitters, receivers etc


구매, 기술, 렌탈 문의  이성종 과장 010-4812-3482 / sjlee3482@gmail.com



Brief Description

The ZVT8 / ZVT20 from Rohde & Schwarz is the first true eight-port/six-port vector network analyzer with a frequency range from 300 kHz to 8 GHz/10 MHz to 20 GHz. The ZVT8 contains up to four internal generators and up to 16 receivers. The ZVT20 includes up to three internal generators and up to 12 receivers. This unique concept with one generator per two test ports makes the ZVT ideal for intermodulation measurements, even on mixers, (true) differential balanced measurements, multireceiver measurements with antennas or high throughput and efficiency in production.


Features & Benefits

The ZVT features the same comprehensive functionality and range of options as the ZVA. Plus, it offers a larger number of ports, i.e. generators and receivers. All applications described here for the ZVA also apply to the ZVT. The instrument offers excellent network analyzer characteristics and comprehensive measurement capabilities for two- to eight-port applications, irrespective of the number of test ports:

   - Extremely fast and accurate measurements on multiport DUTs
   - No delay caused by switch matrix control
   - Greater stability, reproducibility, and flexibility
   - Measurements on balanced DUTs
   - Virtual differential measurement mode (sequential stimulation of single-ended ports, standard mode)
   - True differential measurement mode:
      With eight test ports (four internal sources), up to four true differential signals can be generated and applied to the DUT ports simultaneously
   - Unique performance for measurements on amplifiers, mixers, receivers, frontends, etc.:
   - Arbitrary frequency and power settings for internal generators and receivers as well as external generators
   - Measurement of conversion loss, return loss, leakage, etc., of mixers
   - Intermodulation and hot S-parameter measurements on amplifiers
   - Intermodulation measurements on mixers by means of a single instrument
   - Measurements on double-converting DUTs, with the RF, LO1, and LO2 signals delivered by a single unit
   - Pulsed measurements on amplifiers, mixers, frontends, etc. (for details see "Applications" and "Options" tabs)
   - Frequency- and power-swept point-in-pulse measurements
   - Pulse profile measurements with 12.5 ns resolution on pulses, double pulses and pulse trains with a width smaller than 50 ns; recording time up to 3 ms
   - Multichannel receiver
   - Direct access to up to 16 channels by means of direct generator/receiver access option
   - Parallel, synchronous sampling of channels, e.g. for phase measurements on antenna array
   - Ideal for use in production
   - Parallel measurements on several DUTs increase throughput many times over
   - Reduced instrumentation effort

구매, 기술, 렌탈 문의  이성종 과장 010-4812-3482 / sjlee3482@gmail.com

Specifications
Number of test ports 2 to 8 ( ZVT8)
2 to 6 ( ZVT20)
Frequency range 300 kHz to 8 GHz ( ZVT8)
10 MHz to 20 GHz ( ZVT20)
Measurement time per test point
At 1 MHz IF bandwidth <3.5 ?s
Sampling time per test point
At 5 MHz IF bandwidth (with ZVA-K17option) 430 ns
Measurement time (201 test points) 4.5 ms
Data transfer time (201 test points)
Via IEC/IEEE bus <2.9 ms
Via VX11 over 100 Mbit/s LAN <1.3 ms
Via RSIB over 100 Mbit/s LAN <0.7 ms
Switching time
Between channels <1 ms
Between instrument setups <10 ms
Dynamic range at 10 Hz measurement bandwidth, between test ports 128 dB, typ. 138 dB ( ZVT8)
120 dB, typ. 133 dB ( ZVT20)
Output power at test port >13 dBm, typ. 15 dBm
Power sweep range >50 dB, typ. up to 60 dB
IF bandwidth
Standard 1 Hz to 1 MHz
With ZVA-K17option 5 MHz (10 MHz with restrictions)
With ZVA-K7option 10 MHz (30 MHz with restrictions)
Number of channels, diagrams, traces >100 each
Number of test points per trace 1 to 60001
Operating system Windows XP Embedded
ZVT Vector Network Analyzers             

구매, 기술, 렌탈 문의  이성종 과장 010-4812-3482 / sjlee3482@gmail.com

           
R&S?ZVT Vector Network Analyzers
Frequency ranges from 300 kHz to 20 GHz, with two up to eight test ports


Hardware Options - Additional Test Ports

ZVT8-B6X       Additional Port X (X = port number) 300 kHz to 8 GHz
ZVT20-B6X       Additional Port X (X = port number) 10 MHz to 20 GHz


Base Unit

R&S?ZVAX-TRM Extension Unit
Configurable signal conditioning for measurements on active components


Hardware Options - Direct Channel Access
ZVT8-B16       Direct Generator/Receiver Access for Port X (X = port number) 300 kHz to 8 GHz
ZVT20-B16       Direct Generator/Receiver Access for Port X ( X =port number) 10 MHz to 20 GHz


General Accessories
Accessories                   
Accessories
Overview of Accessories for Network Analyzer from Rohde & Schwarz


Hardware Options - Internal Step Attenuators
ZVT20-B21       Generator Step Attenuator Port 1      70 dB in 10 dB steps, mech., 20 GHz
ZVT20-B23       Generator Step Attenuator Port 3      70 dB in 10 dB steps, mech., 20 GHz
ZVT20-B32       Receiver Step Attenuator Port 2       35 dB in 5 dB steps, mech., 20 GHz
ZVT20-B34       Receiver Step Attenuator Port 4       35 dB in 5 dB steps, mech., 20 GHz


Hardware Options - Other
ZVT20-B11      Internal Combiner (for R&S?ZVT20 only)
ZVAB-B4         Oven Quartz (OCXO)                        


Software Options
ZVAB-K2        Time Domain (TDR) (for ZVA, ZVB, ZVT)
ZVAB-K30       Noise Figure Measurement Noise Figure Measurement on 2 port devices
(for ZVA and ZVT, Option ZVA-K17 (5MHz bandwidth) included) (software license
ZVA-K4          Frequency Conversion                        
ZVA-K5          Vector Corrected Mixer Measurements requires ZVA-B16, ZVA-K4, ZVA 4-port unit recommended
ZVA-K6          True Differential Measurements requires second internal source
ZVA-K7          Pulsed Measurements 3ms recording time
ZVA-K9          Embedded LO Mixer Delay Measurements (requires ZVA-B16)(requires ZVA-K4,ZVA 4-port unit)
ZVA-K10        Long Distance Group Delay Measurement (requires ZVA-B16, ZVA-K9, ZVA-K4 and VISA I/O BIB
ZVA-K27        Two internal pulse generators (for ZVA and ZVT)
ZVA-K31        Frequency Converting Noise Figure MeasureNoise figure measurements on frequency converting DUTs,
                   for ZVA and ZVT, ZVA-K4 and ZVA-K30 required (software license)
ZVA-B7          Pulsed Measurements


25ms recording time, (for two/four port model) Extension

ZVAX24       Extension Unit 10 MHz to 24 GHz (requires ZVA-B16)
               

Hardware Options - Internal PC Control Unit

ZVA-U116       Upgrade CPU FMR7 to FMR11 for ZVA, ZVT Incl. upgrade to Windows Embedded Standard ZVA-U116       Upgrade CPU FMR6 to FMR11 for ZVA                Incl. upgrade to Windows Embedded Standard
ZVA-U116        Upgrade CPU FMR6 to FMR11 for Incl. upgrade to Window Embedded Standard 7
ZVA-U116       UPgrade CPU FMR9 to FMR11 for ZVA, ZVT Incl. upgrade to Windows Embedded Standard 7
ZVAB-U96         All ZVA and ZVT
ZVAB-U96         Upgrade FMR6/5 to FMR9/6 for ZVT ZVT8, ZVT20 Frequency Extension Accessories
R&S?ZVA-Z Millimeter-Wave Converters
Network analysis up to 500 GHz
ZVA-K8       Converter Control Software (for ZVA24, ZVA40, ZVA50, ZVA67 and ZVT20; includ4)
LIST